TECHNICAL DATA / s-SDR

Specifications & selection.

Current prose selection table
ModelOutputTrigger
s-SDR15A203215 A, 24–280 VAC, 47–63 HzZero-cross
s-SDR25A203225 A, 24–280 VAC, 47–63 HzZero-cross
s-SDR15A213215 A, 24–280 VAC, 47–63 HzRandom
s-SDR25A213225 A, 24–280 VAC, 47–63 HzRandom
s-SDR15D613215 A, 60 VDC class; lower limit differs by sourceDC MOSFET
s-SDR25D613225 A, 60 VDC class; lower limit differs by sourceDC MOSFET
Electrical and installation data
ParameterPublished value
Standard control5–24 VDC nominal; image maximum 32 VDC
Optional control5 / 12 / 24 VDC or 90–280 VAC, subject to confirmed model
Nonrepetitive AC surge15 A: 120 A at 10 ms; 25 A: 250 A at 10 ms
Zero-cross timing≤half load-supply cycle + 1 ms
Minimum load, current proseAC: 20 mA; DC: 2 mA
Input/output isolation, prose5000 Vrms; verify applicable test conditions
I/O to base withstand, prose2500 Vrms, 50/60 Hz, 1 minute
Insulation resistance≥100 MΩ at 500 VDC
Ambient−45 to +80 °C, ≤90% RH, no condensation or icing; load derating required
Original outline drawing18 × 86.3 × 85.2 mm; 80 mm main body height; ±0.5 mm source tolerance
Source differences — confirm hardware revision
ItemCurrent proseOriginal image
AC voltage selections240 V class only, 24–280 VACAlso lists 380 V-class models, 48–480 VAC
DC lower voltage0 V5 V
AC leakage / on-state drop≤3 mA at 240 VAC / ≤1.3 V at 25 A5 mA at 220 VAC / 1.5 V at rated load
Input current<20 mA wide-range; 30±5 mA fixed voltage30±5 mA on 5–24 VDC table
Outline / mass18 × 86.5 × 98 mm / 190 g18 × 86.3 × 85.2 mm / promotional 188 g

Selection & installation notes

  • Do not select a 380 V supply from the generic illustration: the current prose excludes that option. Confirm availability and a model-specific rating sheet first.
  • The source labels the switching thresholds as “turn-on ≤4 V” and “turn-off ≥1 V”. These are threshold descriptions, not instructions to turn on below 4 V or turn off above 1 V; obtain guaranteed PLC interface thresholds.
  • An integral heat sink does not remove derating requirements. Above 40 °C, use the exact current-specific curve and provide clearance and airflow.
  • Choose semiconductor fuses using the exact device I²t and fault-current conditions. Nonrepetitive surge current is not continuous or repetitive inrush capacity.
  • Off-state leakage can energize the load. Provide an isolator and remove mains power before service; do not judge functionality using a continuity buzzer.