ENGINEERED FOR INDUSTRIAL ENVIRONMENTS中文官网 ↗
ENMG
TDR / TNR Three-phase AC solid-state relays

ENMG / SOLID-STATE RELAYS

TDR / TNR

Three-phase AC solid-state relays

Three-phase AC switching from one control input, with integrated-heatsink TDR and baseplate-mounted TNR versions.

Request a quote ↗

View specifications ↓

TECHNICAL DATA / TDR / TNR

Specifications & selection.

Original three-phase technical-image selection
ModelCurrent class10 ms non-repetitive surgeHeatsink
TDR40A303240 A300 AIntegrated
TNR15A303215 A120 ARequired separately
TNR25A303225 A250 ARequired separately
TNR40A303240 A300 ARequired separately
Output and input data
ParameterPublished value
Load voltage / frequency48–480 VAC / 47–63 Hz
Repetitive peak voltage800 V
ON drop1.5 V at rated load current
OFF leakage10 mA at 380 VAC
ON / OFF timing≤half supply/current cycle +1 ms respectively
Rated input / maximum in image5–24 VDC / 32 VDC
Input current in image30 ±5 mA; prose says <20 mA for wide-range version
Input-output isolation5000 Vrms; duration not specified
Circuits-baseplate withstand2500 Vrms, 50/60 Hz, 1 minute
Insulation resistance≥100 MΩ at 500 VDC
Input connectorMP1.5AA-3.81, M2 screw; 0.5–1.5 mm²
Output terminalsSix M4 screws
Ambient−45 to +80 °C; ≤90% RH; no condensation or icing
Outline reference
VersionSource information
TDR three-phase image88 × 80 mm front; side dimension 114 mm; verify mounting drawing
TNR prose75 × 100.6 × 39 mm / approximately 280 g; without heatsink
TDR prose alternatives15 A: 590 g; 25/40 A: 889 g; exact variant confirmation needed

Selection & installation notes

  • The original chart lists only the 40 A integrated TDR. Prose additionally offers 15/25 A TDR and 24–280 VAC/random variants; obtain an exact datasheet before ordering those extensions.
  • Input current and TDR dimensions differ between prose and technical images. Confirm driver capacity, mechanical clearance and actual thermal configuration.
  • The threshold rows specify ON ≤4 V and OFF ≥1 V as threshold limits; they are not instructions to drive ON below 4 V or hold OFF above 1 V. Confirm guaranteed logic levels with the manufacturer.
  • TDR/TNR are AC-output products. Generic MOSFET/DC-output and DC-lamp diagnostic instructions on the source page are not applicable to their normal operation.
  • Coordinate semiconductor protection, maximum phase current and thermal derating. TNR needs a separately designed heatsink; its ratings cannot inherit TDR cooling conditions. Provide upstream isolation because OFF leakage remains.

Based on the official Chinese product page and selection charts ↗. Checked 2026-09-15. Confirm the current specification for the exact model when ordering.

TECHNICAL RESOURCES

Plan your integration.

ENMG relays — English product-family brochure.

This is a product-family brochure. Request a model-specific datasheet and installation drawing with your inquiry.